Alco-Sensor RBT VXL Full Data System

$ 2,505.00$ 2,797.25

Description

Alco-Sensor RBT VXL Full Data System

The Alco-Sensor RBT VXL full data system is a premium breath alcohol testing device from Intoximeters. This device is programmed with both a Quick Test mode and Full Data mode so the operator determines the amount of testing information collected and the speed of each test.

  • Approved by the U.S. DOT as an evidential breath alcohol testing device
  • Great for Regulated and Non-Regulated workplace testing programs
  • Evidential accuracy exceeds +/- .005 at .100 BrAC
  • Programmed with DOT and NRC testing protocols
  • Automatic and manual breath sampling capability
  • Intuitive menus prompt the operator through a DOT testing sequence, greatly reducing operator errors
  • Automatically initiates a :15 wait period following a positive screening test of .02
  • Automatically initiates a confirmation test following the :15 wait period
  • Keyboard allows operator to input testing data such as BAT name and identification number, employee name and identification number, and company name (data is reflected in test print out)
  • Store hundreds of tests in the device’s memory
  • The Martel thermal printer prints results without the mess of ink printers
  • Operates independently of the Martel thermal printer, allowing the operator to test the subject without being tethered to the printer
  • Operator places the Alco-Sensor VXL into the docking station to quickly print test results. This fail-safe printing method removes any question about the integrity of the printed test result, and removes the issues that sometimes arise with wireless communication technology

This device is programmed with DOT quick test and full data testing modes, so you control the amount of data to collect during the test and the speed of the test.

Quick Test mode collects the following data:

  • Subject’s name
  • Subject’s ID number
  • Reason for the test

Full Data mode collects the following data:

  • Subject’s name
  • Subject’s ID number
  • Company name
  • BAT name
  • BAT ID number
  • Reason for the test
Specs

Alco-Sensor RBT VXL Specifications

Specifications
Sensor typeElectrochemical Oxidation (fuel cell)
Range of measurement.000 – .400 BrAC
Accuracy and precisionU.S. DOT approved for evidential use
Breath samplingAutomatic with manual override
Response time5 – 10 seconds negative results, 10 – 30 seconds positive results
Power requirementAlco-Sensor V: 4 AA batteries (included), 1500+ testsImpact

Printer: rechargeable batteries, 75+ tests

Slip Printer: 120 volt AC

Test modeDirect
CalibrationMicroprocessor controlled, using gas or wet bath simulator
Memory1,000 + tests, browse memory, reprint any test
Print capabilityYes, with Thermal or Slip printer
Temperature range0 – 50 degrees C
Size14″ X 14″ X 5, 12 lbs (in nylon carrying case)
WarrantyTwo year parts and labor
Standard Equipment

RBT VXL Standard Product

  • Alco-Sensor VXL
  • Thermal Printer
  • Keyboard
  • Docking station and cables
  • 100 mouthpieces
  • Nylon Carrying Case
  • Printer paper
  • Manual
  • Battery charger
  • Two year factory warranty
  • Available bundled with gas tank and regulator
Calibration

RBT VXL Calibration Information

Accuracy Checks and Calibration Adjustments

There are two procedures used to maintain the accuracy of alcohol testing instruments. The operator performs the Accuracy Check procedure to determine if the instrument is reading correctly. If the Accuracy Check procedure determines that the instrument is not reading correctly, the operator performs a Calibration Adjustment procedure. The operator must have acceptable Accuracy Check and Calibration Equipment to perform the Accuracy Check and Calibration Adjustment procedure.

Frequency of Accuracy Checks

In general, Intoximeters recommends performing Accuracy Checks at least once a month. Programs may develop their own policies to perform Accuracy Checks at more frequent intervals.

Frequency of Calibration Adjustments

In general, Intoximeters does not require the operator to perform periodic Calibration Adjustments. Calibration Adjustments are performed only when an Accuracy Check procedure determines that the instrument is not reading correctly. Agencies may develop their own policies that require periodic Calibration Adjustments.

Accuracy Check and Calibration Equipment

The following equipment may be used to perform Accuracy Checks and Calibration Adjustments with the Alco-Sensor VXL.
Alcohol Gas Tank and Regulator 
Simulator

Product Library

Alco-Sensor RBT VXL Datasheet

Reviews

Share your thoughts!

Let us know what you think...

What others are saying

There are no contributions yet.

×

Login

Register

Loading...

Your personal data will be used to support your experience throughout this website, to manage access to your account, and for other purposes described in our Privacy policy.

Apply for Tax Exempt Status

Continue as a Guest

Don't have an account? Sign Up