Alco-Sensor RBT VXL Data Lite System

SKU: 215-DL
(1 customer review)

$ 2,150.00

Economical Breathalyzer with Fast and Easy Testing.

The Alco-Sensor RBT VXL Data Lite System comes with a DOT Quick Test protocol for fast and easy testing. Display messages guide the operator through the test sequence, reducing operator error. Each system includes:

  • Alco-Sensor VXL and docking station
  • Rugged nylon carry case
  • Keyboard
  • Martel thermal printer and printer paper
  • 100 mouthpieces
  • 2-year factory warranty

same day shipping

Description

Alco-Sensor RBT VXL Data Lite System

The Alco-Sensor RBT VXL Data Lite system is an economical and portable breath alcohol testing device from Intoximeters. This system is programmed with a DOT Quick Test protocol which quickly guides the operator through a DOT testing sequence, reducing operator error. The full keyboard makes data entry fast and easy. The system includes a NRC testing protocol that can be selected from the main menu.

  • Approved by the U.S. DOT as an evidential breath alcohol testing device
  • Great for Regulated and Non-Regulated workplace testing programs
  • Programmed with DOT and NRC testing protocols
  • Evidential accuracy exceeds +/- .005 at .100 BrAC
  • Easy to read prompts guide the operator through the testing sequence, greatly reducing operator errors
  • Intuitive menus gives the operator quick access to DOT quick test protocols and multiple features
  • Automatic and manual breath sampling capability
  • Automatically initiates a :15 wait period following a positive screening test of .02
  • Automatically initiates a confirmation test following the :15 wait period
  • Hundreds of tests can be stored and printed in the device’s memory
  • The Martel thermal printer prints results without the mess of ink printers
  • Operates independently of the Martel thermal printer, allowing the operator to test the subject without being tethered to the printer
  • Operator places the Alco-Sensor VXL into the docking station to quickly print test results. This fail-safe printing method removes any question about the integrity of the printed test result, and removes the issues that sometimes arise with wireless communication technology

This device is programmed with a DOT quick test so each test is fast and easy.

DOT Quick Test mode collects the following data:

  • Reason for the test
Specs

Alco-Sensor RBT VXL Specifications

Specifications
Sensor typeElectrochemical Oxidation (fuel cell)
Range of measurement.000 – .400 BrAC
Accuracy and precisionU.S. DOT approved for evidential use
Breath samplingAutomatic with manual override
Response time5 – 10 seconds negative results; 10 – 30 seconds positive results
Power requirementAlco-Sensor V: 4 AA batteries (included), 1500+ testsImpact

Printer: rechargeable batteries, 75+ tests

Test modeDirect
CalibrationMicroprocessor controlled, using dry gas or wet bath simulator
Memory1,000 + tests, browse memory, reprint any test
Print capabilityYes, with Martel, Impact or Slip printer
Temperature range0 to 50 degrees C
Size14″ X 14″ X 5, 12 lbs (in nylon carrying case)
WarrantyTwo year parts and labor
Standard Equipment

RBT VXL Standard Product

  • Two year factory warranty
  • Alco-Sensor VXL
  • Martel Thermal Printer
  • Keyboard
  • Docking station and cables
  • 100 mouthpieces
  • Nylon Carrying Case
  • Printer paper
  • Batteries
  • Battery charger
  • Manual
Calibration

RBT VXL Calibration Information

Accuracy Checks and Calibration Adjustments

There are two procedures used to maintain the accuracy of alcohol testing instruments. The operator performs the Accuracy Check procedure to determine if the instrument is reading correctly. If the Accuracy Check procedure determines that the instrument is not reading correctly, the operator performs a Calibration Adjustment procedure. The operator must have acceptable Accuracy Check and Calibration Equipment to perform the Accuracy Check and Calibration Adjustment procedure.

Frequency of Accuracy Checks

In general, Intoximeters recommends performing Accuracy Checks at least once a month. Programs may develop their own policies to perform Accuracy Checks at more frequent intervals.

Frequency of Calibration Adjustments

In general, Intoximeters does not require the operator to perform periodic Calibration Adjustments. Calibration Adjustments are performed only when an Accuracy Check procedure determines that the instrument is not reading correctly. Agencies may develop their own policies that require periodic Calibration Adjustments.

Accuracy Check and Calibration Equipment

The following equipment may be used to perform Accuracy Checks and Calibration Adjustments with the Alco-Sensor VXL.
Alcohol Gas Tank and Regulator 
Simulator

Product Library

Alco-Sensor RBT VXL Datasheet

Reviews

Share your thoughts!

5 out of 5 stars

1 review

Let us know what you think...

What others are saying

  1. Great breathalyzer. Great service

    Josh J

    The Alco-Sensor RBT VXL breathalyzer is so easy to use. Customer service is always friendly and helpful. Orders arrive on time.

    Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

    Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

×

Login

Register

Loading...

Your personal data will be used to support your experience throughout this website, to manage access to your account, and for other purposes described in our privacy policy.

Apply for Tax Exempt Status

Continue as a Guest

Don't have an account? Sign Up