Login / Register | 0 items - $ 0.00 CONTACT US

AlcoPro - Drug and Alcohol Testing Products & DOT Training

  • Products
  • Training
    • DOT Drug and Alcohol Training
    • Employer Substance Abuse Awareness Training
    • Hotels in Knoxville
    • Training Materials
    • DOT Regulations Knowledge Base
  • Knowledge Base
  • Repairs & Services
  • Resources
    • Catalogs
    • Knowledge Base
    • Buyer’s Guide
    • Product Document Library
    • Drug Test Finder
    • Drink Wheel
    • Window of Detection Tool
    • Breath Alcohol Instrument Mouthpiece Chart
  • News
    • News
    • AlcoPro Blog
    • Sign Up – AlcoPro Blog
  • Customer Service
    • Order & Return Policy
    • Shipping Information
    • Apply for Tax Exempt Status
    • Satisfaction & Warranty Policy
    • Repair Services and Technical Support
    • Privacy Policy
    • Customer Reviews
  • Contact Us
    • Contact Us
    • Quote Request
    • Catalog Request
    • Product Sample Request
    • BAC Wheel Request
    • Customer Reviews
  • About Us

800.227.9890

Follow Us on FacebookFollow Us on TwitterFollow Us on LinkedIn

§ 40.65 What does the collector check for when the employee presents a specimen?

  • Home
  • /
  • Knowledge-base
  • /
  • DOT
  • /
  • Regulations
  • /
  • § 40.65 What does the collector check for when …

As a collector, you must check the following when the employee gives the collection container to you:

(a) Sufficiency of specimen. You must check to ensure that the specimen contains at least 45 mL of urine.

(1) If it does not, you must follow “shy bladder” procedures (see §40.193(b)).

(2) When you follow “shy bladder” procedures, you must discard the original specimen, unless another problem (i.e., temperature out of range, signs of tampering) also exists.

(3) You are never permitted to combine urine collected from separate voids to create a specimen.

(4) You must discard any excess urine.

(b) Temperature. You must check the temperature of the specimen no later than four minutes after the employee has given you the specimen.

(1) The acceptable temperature range is 32–38 °C/90–100 °F.

(2) You must determine the temperature of the specimen by reading the temperature strip attached to the collection container.

(3) If the specimen temperature is within the acceptable range, you must mark the “Yes” box on the CCF (Step 2).

(4) If the specimen temperature is outside the acceptable range, you must mark the “No” box and enter in the “Remarks” line (Step 2) your findings about the temperature.

(5) If the specimen temperature is outside the acceptable range, you must immediately conduct a new collection using direct observation procedures (see §40.67).

(6) In a case where a specimen is collected under direct observation because of the temperature being out of range, you must process both the original specimen and the specimen collected using direct observation and send the two sets of specimens to the laboratory. This is true even in a case in which the original specimen has insufficient volume but the temperature is out of range. You must also, as soon as possible, inform the DER and collection site supervisor that a collection took place under direct observation and the reason for doing so.

(7) In a case where the employee refuses to provide another specimen (see §40.191(a)(3)) or refuses to provide another specimen under direct observation (see §40.191(a)(4)), you must notify the DER. As soon as you have notified the DER, you must discard any specimen the employee has provided previously during the collection procedure.

(c) Signs of tampering. You must inspect the specimen for unusual color, presence of foreign objects or material, or other signs of tampering (e.g., if you notice any unusual odor).

(1) If it is apparent from this inspection that the employee has tampered with the specimen (e.g., blue dye in the specimen, excessive foaming when shaken, smell of bleach), you must immediately conduct a new collection using direct observation procedures (see §40.67 ).

(2) In a case where a specimen is collected under direct observation because of showing signs of tampering, you must process both the original specimen and the specimen collected using direct observation and send the two sets of specimens to the laboratory. This is true even in a case in which the original specimen has insufficient volume but it shows signs of tampering. You must also, as soon as possible, inform the DER and collection site supervisor that a collection took place under direct observation and the reason for doing so.

(3) In a case where the employee refuses to provide a specimen under direct observation (see §40.191(a)(4)), you must discard any specimen the employee provided previously during the collection procedure. Then you must notify the DER as soon as practicable.

[65 FR 79526, Dec. 19, 2000, as amended at 66 FR 41950, Aug. 9, 2001] 

ABOUT ALCOPRO

Since 1982, AlcoPro has supplied and manufactured the most accurate drug and alcohol testing instruments, kits, and supplies for professional use. We take pride in maintaining our industry-wide reputation for accuracy and quality as we help you—our top priority—perform alcohol and drug screenings and tests with greater precision and confidence.

Subscribe to Our Blog

  • This field is for validation purposes and should be left unchanged.

800.227.9890
Follow Us on FacebookFollow Us on TwitterFollow Us on LinkedInFollow Us on YouTube

Privacy Policy

© 2023 AlcoPro.
All Rights Reserved.

Custom Website Design & Development by VIEO Design